{"id":311,"date":"2018-09-12T16:11:11","date_gmt":"2018-09-12T23:11:11","guid":{"rendered":"https:\/\/vancouver.labs.wsu.edu\/icpms\/?page_id=311"},"modified":"2018-09-17T19:03:23","modified_gmt":"2018-09-18T02:03:23","slug":"sample-submission","status":"publish","type":"page","link":"https:\/\/vancouver.labs.wsu.edu\/icpms\/sample-submission\/","title":{"rendered":"Sample Submission"},"content":{"rendered":"<br \/>\n<section id=\"builder-section-1536793862906\" class=\"row single gutter pad-top\">\n<div style=\"\" class=\"column one \">\n<div id=\"general-wrapper\">\n<h2>Sample Submission<\/h2>\n<div id=\"instructions\">\n      Find the preparation guide for the instrument needed below. The instrument availability calendar can be found <a href=\"https:\/\/vancouver.labs.wsu.edu\/icpms\/events\" style=\"font-weight:bold\">here.<\/a><\/p>\n<h5 id=\"prepbutton1\">ICP-MS Preparation Guide <img decoding=\"async\" class=\"arrow\" id=\"arrow4\" src=\"https:\/\/wpcdn.web.wsu.edu\/wp-vancouverlabs\/uploads\/sites\/2136\/2018\/09\/9654-1.png\"><\/h5>\n<div id=\"icpms-prep\">\n         <strong>Scheduling and requesting access to the instrument<\/strong><\/p>\n<ol>\n<li>Request instrument runtime at least 10 days in advance. Access to the instrument within a shorter timeframe is made by exception only.<\/li>\n<li>Submit a completed <a href=\"https:\/\/forms.office.com\/Pages\/ResponsePage.aspx?id=ceQrtfH3tEeoeQx5m7U9tT4pts-g2-lEtndeOUPm29JUREVSVEkwNzFYSE85NVMzWlA2VUdSOVRMNC4u\"><strong>Sample Submittal Form<\/strong><\/a>. New users should complete <strong><a href=\"https:\/\/vancouver.labs.wsu.edu\/icpms\/new-users\">New User Registration<\/a><\/strong> before submitting a sample.<\/li>\n<\/ol>\n<p>         <strong>Sample preparation prior to instrument run*<\/strong><\/p>\n<ol start=\"3\">\n<li>Have your samples prepared 1 day prior to the scheduled run.\n<ol>\n<li>Samples must be acidified with nitric acid to 1-2% nitric acid and filtered to &lt;0.7um.\n<ol>\n<li>Use trace metal grade nitric acid if analyzing for trace metals.<\/li>\n<\/ol>\n<\/li>\n<li>Samples must be in 15mL centrifuge tubes containing 5-15mL of sample.<\/li>\n<\/ol>\n<\/li>\n<li>Make sure to arrive in the lab at the scheduled runtime to load your samples into the autosampler.<\/li>\n<\/ol>\n<p>*If you need assistance with steps 3-4, you may request additional time with the lab manager.<\/p>\n<p>      <strong>Diagnostics during the run<\/strong><\/p>\n<p>      <strong>Unless you are an experienced user with the instrument, the lab manager will complete these steps (typically takes ~15-30 minutes depending on the number of analytes)<\/strong><\/p>\n<ol start=\"5\">\n<li>Verify the calibration curves are successful by comparing observed ppm values to the actual concentrations listed in the ICP-MS Data Analysis software.\n<ol>\n<li>Select alternate internal standards as needed for each analyte.<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n<p>      <strong>Post run<\/strong><\/p>\n<ol start=\"6\">\n<li>Save your data and remove your samples.\n<ol>\n<li>Copy the data and paste into excel.<\/li>\n<li>Save the excel data to your flash drive.<\/li>\n<li>Remove your samples from the autosampler.<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n<\/div>\n<h5 id=\"prepbutton2\">IC Preparation Guide <img decoding=\"async\" class=\"arrow\" id=\"arrow5\" src=\"https:\/\/wpcdn.web.wsu.edu\/wp-vancouverlabs\/uploads\/sites\/2136\/2018\/09\/9654-1.png\"><\/h5>\n<div id=\"ic-prep\">\n         <strong>Scheduling and requesting access to the instrument<\/strong><\/p>\n<ol>\n<li>Request instrument runtime at least 10 days in advance. Access to the instrument within a shorter timeframe is made by exception only.<\/li>\n<li>Submit a completed <a href=\"https:\/\/forms.office.com\/Pages\/ResponsePage.aspx?id=ceQrtfH3tEeoeQx5m7U9tT4pts-g2-lEtndeOUPm29JUREVSVEkwNzFYSE85NVMzWlA2VUdSOVRMNC4u\"> <strong>Sample Submittal Form<\/strong><\/a>. New users should complete <strong><a href=\"https:\/\/vancouver.labs.wsu.edu\/icpms\/new-users\">New User Registration<\/a><\/strong> before submitting a sample.<\/li>\n<\/ol>\n<p>        <strong>Sample preparation prior to instrument run*<\/strong><\/p>\n<ol start=\"3\">\n<li>Have your samples prepared 1 day prior to the scheduled run.\n<ol>\n<li>Triple rinse 0.5mL IC sample vials and caps with milli-q water.<\/li>\n<li>Clearly label sample vials.<\/li>\n<li>Pour sample into sample vials and add vial caps.<\/li>\n<li>Tap the side of each vial to dislodge any air bubbles in the sample vial.\n<ol>\n<li>Air bubbles injected into the IC can result in poor data for your run and the run of others.<\/li>\n<\/ol>\n<\/li>\n<li>Use the sample loading tool to press vial caps into sample vials until flush with the top of the vials.<\/li>\n<li>Place sample vials in a portable vial rack in the sequence they will be analyzed in.<\/li>\n<li>Refrigerate sample vials until analysis.<\/li>\n<\/ol>\n<\/li>\n<li>Make sure to arrive in the lab at the scheduled runtime to load your samples into the autosampler.<\/li>\n<\/ol>\n<p>&nbsp;<\/p>\n<p>*If you need assistance with steps 3-4, you may request additional time with the lab manager.<\/p>\n<p>          <strong>Diagnostics during the run<\/strong><\/p>\n<p>          <strong>Unless you are an experienced user with the instrument, the lab manager will complete these steps (typically takes ~15 minutes)<\/strong><\/p>\n<ol start=\"5\">\n<li>During the run, verify the calibration curves are successful by comparing observed ppm values to the actual concentrations listed on the wall.\n<ol>\n<li>Double-click a chromatogram from your run to open the Chromelion Chromotography Studio software (if not already open).<\/li>\n<li>Click the Report Designer tab on the left.<\/li>\n<li>Click the Summary tab on the bottom.<\/li>\n<li>Scroll to \u201cSummary Amount PPM\u201d to view observed values.<\/li>\n<li>Click the Calibration tab to view R-Square and graphs for calibration curves.<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n<p>         <strong>Post run<\/strong><\/p>\n<ol start=\"6\">\n<li>Verify sample peaks were identified and export your data to excel.\n<ol>\n<li>Double-click a chromatogram from your run to open the Chromelion Chromotography Studio software (if not already open).<\/li>\n<li>Click the Report Designer tab on the left.<\/li>\n<li>Click the Summary tab on the bottom.<\/li>\n<li>Scroll to \u201cSummary Amount PPM\u201d to view observed values.<\/li>\n<li>Copy (Ctrl+C) summary data and paste into Excel (Ctrl+V).<\/li>\n<li>Save excel data to a flash drive.<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n<ol start=\"7\">\n<li>Remove sample and standard vials from the autosampler\n<ol>\n<li>Open the autosampler lid and press the \u201cCAROUSEL RELEASE\u201d button to disengage the plunger from the last vial (It takes up to 30 seconds for the plunger to fully disengage).<\/li>\n<li>Once the \u201cCAROUSEL\u201d light is off, remove sample vials and close the autosampler lid.<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n<\/div>\n<\/div><\/div>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p> <\/p>\n<h2>Sample Submission<\/h2>\n<p> Find the preparation guide for the instrument needed below. The instrument availability calendar can be found <a href=\"https:\/\/vancouver.labs.wsu.edu\/icpms\/events\" style=\"font-weight:bold\">here.<\/a><\/p>\n<h5 id=\"prepbutton1\">ICP-MS Preparation Guide <img decoding=\"async\" ... <a href=\"https:\/\/vancouver.labs.wsu.edu\/icpms\/sample-submission\/\" class=\"more-link\"\/><span class=\"more-default\">&raquo; More &#8230;<\/span><\/h5>\n","protected":false},"author":10788,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"template-builder.php","meta":{"_wsuwp_accessibility_report":[]},"wsuwp_university_location":[],"wsuwp_university_org":[],"_links":{"self":[{"href":"https:\/\/vancouver.labs.wsu.edu\/icpms\/wp-json\/wp\/v2\/pages\/311"}],"collection":[{"href":"https:\/\/vancouver.labs.wsu.edu\/icpms\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/vancouver.labs.wsu.edu\/icpms\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/vancouver.labs.wsu.edu\/icpms\/wp-json\/wp\/v2\/users\/10788"}],"replies":[{"embeddable":true,"href":"https:\/\/vancouver.labs.wsu.edu\/icpms\/wp-json\/wp\/v2\/comments?post=311"}],"version-history":[{"count":30,"href":"https:\/\/vancouver.labs.wsu.edu\/icpms\/wp-json\/wp\/v2\/pages\/311\/revisions"}],"predecessor-version":[{"id":870,"href":"https:\/\/vancouver.labs.wsu.edu\/icpms\/wp-json\/wp\/v2\/pages\/311\/revisions\/870"}],"wp:attachment":[{"href":"https:\/\/vancouver.labs.wsu.edu\/icpms\/wp-json\/wp\/v2\/media?parent=311"}],"wp:term":[{"taxonomy":"wsuwp_university_location","embeddable":true,"href":"https:\/\/vancouver.labs.wsu.edu\/icpms\/wp-json\/wp\/v2\/wsuwp_university_location?post=311"},{"taxonomy":"wsuwp_university_org","embeddable":true,"href":"https:\/\/vancouver.labs.wsu.edu\/icpms\/wp-json\/wp\/v2\/wsuwp_university_org?post=311"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}